HMM
(Human Metal Model)

HMM complies with IEC-6100-4-2 testing on board, wafer, package, or sub assembly. Our GTS Tarvos HMM pulser delivers waveforms through a 50Ω line directly to the DUT. The controlled impedance path removes the uncertainties of gun based testing. Each pulse is monitored and measured.

We may also check leakage between pulses and compare for damage assessment. DUT impedance is measured to track heating effects. Waveforms up to 8kV are available.